RSS-200-A - 

Sensor, Current; 200A Pri:DC to 25kHz; Measure AC & DC currents; 1.26In.Dia.3.54In.

FW Bell RSS-200-A
声明:图片仅供参考,请以实物为准!
制造商:
FW Bell FW Bell
制造商产品编号:
RSS-200-A
仓库库存编号:
70103874
技术数据表:
View RSS-200-A Datasheet Datasheet
订购热线: 400-900-3095  0755-21000796, QQ:800152669, Email:sales@szcwdz.com
由于产品数据库庞大,部分产品信息可能未能及时更新,下单前请与销售人员确认好实时在库数量,谢谢合作!

RSS-200-A产品概述



The RS/RSS-A Series of current sensors accurately measure AC and DC currents and provide electrical isolation between the circuit being measured and the output of the sensor. The RS-A Series operates from dual DC supply voltages of ±12 to ±18 volts. The RSS-A Series operates from a single DC supply voltage of +12 to +18 volts with a zero current output of 6 volts DC. Nominal current ranges of 100 to 1000 amps are available with all models available in the same standard package and have the versatility to be panel or bulkhead mounted.

RSS-200-A产品信息

  Current, Primary  200 A  
  Current, Switching  200 A  
  Diameter, Inner  1.26 in. (Max.)  
  For Use With  Measure AC and DC currents  
  Frequency Response  DC to 25 kHz  
  Function  Current  
  Height  4.22" (107.2mm)  
  Length  3.54" (89.916mm)  
  Mounting Type  Panel Mount/Bulkhead  
  Output  Current  
  Range, Measurement  500 A  
  Standards  UL Listed  
  Supply Voltage  18 VDC  
  Technology  Hall Effect  
  Termination  Wired Connector  
  Type  Hall Effect  
  Voltage, Switching  8 mV  
  Width  0.071" (1.8mm)  
关键词         

RSS-200-A相关搜索

Current, Primary 200 A  FW Bell Current, Primary 200 A  Current Transducers Current, Primary 200 A  FW Bell Current Transducers Current, Primary 200 A   Current, Switching 200 A  FW Bell Current, Switching 200 A  Current Transducers Current, Switching 200 A  FW Bell Current Transducers Current, Switching 200 A   Diameter, Inner 1.26 in. (Max.)  FW Bell Diameter, Inner 1.26 in. (Max.)  Current Transducers Diameter, Inner 1.26 in. (Max.)  FW Bell Current Transducers Diameter, Inner 1.26 in. (Max.)   For Use With Measure AC and DC currents  FW Bell For Use With Measure AC and DC currents  Current Transducers For Use With Measure AC and DC currents  FW Bell Current Transducers For Use With Measure AC and DC currents   Frequency Response DC to 25 kHz  FW Bell Frequency Response DC to 25 kHz  Current Transducers Frequency Response DC to 25 kHz  FW Bell Current Transducers Frequency Response DC to 25 kHz   Function Current  FW Bell Function Current  Current Transducers Function Current  FW Bell Current Transducers Function Current   Height 4.22" (107.2mm)  FW Bell Height 4.22" (107.2mm)  Current Transducers Height 4.22" (107.2mm)  FW Bell Current Transducers Height 4.22" (107.2mm)   Length 3.54" (89.916mm)  FW Bell Length 3.54" (89.916mm)  Current Transducers Length 3.54" (89.916mm)  FW Bell Current Transducers Length 3.54" (89.916mm)   Mounting Type Panel Mount/Bulkhead  FW Bell Mounting Type Panel Mount/Bulkhead  Current Transducers Mounting Type Panel Mount/Bulkhead  FW Bell Current Transducers Mounting Type Panel Mount/Bulkhead   Output Current  FW Bell Output Current  Current Transducers Output Current  FW Bell Current Transducers Output Current   Range, Measurement 500 A  FW Bell Range, Measurement 500 A  Current Transducers Range, Measurement 500 A  FW Bell Current Transducers Range, Measurement 500 A   Standards UL Listed  FW Bell Standards UL Listed  Current Transducers Standards UL Listed  FW Bell Current Transducers Standards UL Listed   Supply Voltage 18 VDC  FW Bell Supply Voltage 18 VDC  Current Transducers Supply Voltage 18 VDC  FW Bell Current Transducers Supply Voltage 18 VDC   Technology Hall Effect  FW Bell Technology Hall Effect  Current Transducers Technology Hall Effect  FW Bell Current Transducers Technology Hall Effect   Termination Wired Connector  FW Bell Termination Wired Connector  Current Transducers Termination Wired Connector  FW Bell Current Transducers Termination Wired Connector   Type Hall Effect  FW Bell Type Hall Effect  Current Transducers Type Hall Effect  FW Bell Current Transducers Type Hall Effect   Voltage, Switching 8 mV  FW Bell Voltage, Switching 8 mV  Current Transducers Voltage, Switching 8 mV  FW Bell Current Transducers Voltage, Switching 8 mV   Width 0.071" (1.8mm)  FW Bell Width 0.071" (1.8mm)  Current Transducers Width 0.071" (1.8mm)  FW Bell Current Transducers Width 0.071" (1.8mm)  