In-Line Flow Measurement:
AWM5000 Series Microbridge Mass Airflow Sensors feature a venturi type flow housing. They measure flow as high as 20 standard liters per minute (SLPM) while inducing a maximum pressure drop of 2.25 N H2O. The microbridge chip is in direct contact with the flow stream, greatly reducing error possibilities due to orifice or bypass channel clogging.
Rugged, Versatile Package:
The rugged plastic package has been designed to withstand common mode pressures up to 50 PSI, and the small sensing element allows 100 Gs of shock without compromising performance. The included “AMP” compatible connector provides reliable connection in demanding applications.
On-Board Signal Conditioning:
Each AWM5000 sensor contains circuitry which performs amplification, linearization, temperature compensation and gas calibration. A 1 to 5 VDC linear output is possible for all listings regardless of flow range (5, 10, 15 or 20 SLPM) or calibration gas (nitrogen, carbon dioxide, nitrous oxide or argon). All calibration is performed by active laser trimming.
Features:
High Flow Design
Linear Voltage Output
Venturi Design
Active Laser Trimming for Improved Interchangeability
Specifications:
Calibrated for Nitrogen Gas
Operating Temperature: –4° to +158°F