CAH05A2BG - 

Relay; E-Mech, Curr mtr; .5-5A, FAULT TRIP CRRNT RNG; 120VAC; TRP DELAY .5-50 sec

Macromatic CAH05A2BG
声明:图片仅供参考,请以实物为准!
制造商产品编号:
CAH05A2BG
仓库库存编号:
70368302
技术数据表:
View CAH05A2BG Datasheet Datasheet
订购热线: 400-900-3095  0755-21000796, QQ:800152669, Email:sales@szcwdz.com
由于产品数据库庞大,部分产品信息可能未能及时更新,下单前请与销售人员确认好实时在库数量,谢谢合作!

CAH05A2BG产品概述

Macromatic’s CAH Series Current Sensing Relays detect either an overcurrent or undercurrent fault (selectable). These relays include user-adjustable settings for Fault Trip Current & Time Delay on Fault Trip as well as an LED to indicate fault condition. The encapsulated construction offer protection in harsh conditions. Applications such as monitoring for locked rotor or load loss condition, open heater or lamp, and process control are perfect for these products.
Features:
  • Monitors AC current, 0.5-5A
  • Trip Delay: 0.5-50 Sec
  • Timing Range: Sensing delay on startup: 0.4 sec
  • Input 120V
  • Three separate adjustable Fault Trip Current ranges covering 0.5-50 amperes
  • Built-in current transformer allows easy access & multiple loops for increased sensitivity
  • Adjustable time delay on fault trip
  • LED indicated fault condition
  • Encapsulated for protection in harsh environments
  • Pilot Duty Rating

    Specifications:
  • 10A SPDT output contacts
  • Temperature: –28°C to 65°C
  • Dimensions: 1.5" D × 2.5" W × 3.5" H

    Description of Function:
    Overcurrent Sensing
    After input voltage is applied & the sensing delay on power-up (ts) is completed, the unit will begin sensing for a fault condition. A fault will occur when the monitored AC current (I) goes above the Fault Trip Current setting & remains above the Reset level for a period longer than the adjustable time delay period (t). The LED will turn ON immediately and the relay will energize after the time delay on pick-up (t) is completed. The relay will de-energize & the LED will turn OFF when the monitored AC current goes below the Reset level.

    Undercurrent Sensing
    After input voltage is applied & the sensing delay on power-up (ts) is completed, the unit will begin sensing for a fault condition. A fault will occur when the monitored AC current (I) goes below the Fault Trip Current setting & remains below the Reset level for a period longer than the adjustable time delay period (t). The LED will turn ON immediately and the relay will energize after the time delay on pick-up (t) is completed. The relay will de-energize & the LED will turn OFF when the monitored AC current goes above the Reset level.