TR-60221产品概述
Upon application of input voltage, a preset time begins. At the end of the preset time, the relay contacts transfer. Input voltage must be removed and reapplied to reset the time delay relay.
Features:
16 Timing Ranges in a Single Timer
Covers 0.1 S to 2 H (0.6 S to 24 H on TR-631, TR-651 and TR-661 Units and 0.1 S to 30 M on TR-606 Units)
User Selects Desired Time Range by Setting a Rotary Switch — No Math Required or DIP Switches to Set
Adjust within Selected Range Using Potentiometer
Standard 8- or 11-Pin Octal Socket Mounting
All Units Operate on Both AC and DC
Repeat Cycle and Delayed Interval Units Have Independently Selectable and Adjustable ON and OFF Times
Specifications:
DPDT 10 A @ 240 VAC/30 VDC
0.1% Repeat Accuracy
Temperature: –28° to +65°C
Dimensions: 1.7" × 2.4" × 3.5"