773103产品概述
Features:
Can be configured in the PNOZmulti Configurator
Positive-guided relay outputs: – 2 safety outputs Depending on the application, up to PL e of EN ISO 13849-1 and up to SIL CL 3 of EN IEC 62061
Semiconductor outputs: – 4 safety outputs Depending on the application, up to PL e of EN ISO 13849-1 and up to SIL CL 3 of EN IEC 62061, – 1 output for standard applications
4 test pulse outputs
1 cascading input and output; can also be used as a standard output
20 inputs for connecting, for example: – E-STOP pushbuttons, – Two-hand pushbuttons, – Safety gate limit switches, – Start buttons, – Light beam devices, – Scanners, – Enabling switches, – PSEN, – Operating mode selector switches, – Safety mats
Muting function Overview Operating Manual PNOZ m1p (ETH) 20878-EN-15 8
LED indicator for: – Diagnostics, – Supply voltage, – Output circuits, – Input circuits
Test pulse outputs used to monitor shorts across the inputs
Monitoring of shorts between the safety outputs
Expansion modules can be connected
Integrated interfaces: – PNOZ m1p: Serial interface RS232, – PNOZ m1p ETH: 2 Ethernet interfaces
Plug-in connection terminals: either spring-loaded terminal or screw terminal available as an accessory
Coated version: Increased environmental requirements