amphenol代理商
专业销售Amphenol(安费诺)全系列产品-英国2号仓库
库存查询
美国1号分类选型新加坡2号分类选型英国10号分类选型英国2号分类选型日本5号分类选型

在本站结果里搜索:    
热门搜索词:  Connectors  8910DPA43V02  Amphenol  UVZSeries 160VDC  70084122  IM21-14-CDTRI

CUB4CL40 - 

Indicator 9 to 28 VDC 3-1/2 Screw-ClampLCD, LED Panel EEPROM 1.5 lbs

Red Lion Controls CUB4CL40
声明:图片仅供参考,请以实物为准!
制造商产品编号:
CUB4CL40
仓库库存编号:
70030217
技术数据表:
View CUB4CL40 Datasheet Datasheet
订购热线: 400-900-3095  0755-21000796, QQ:800152669, Email:sales@szcwdz.com
由于产品数据库庞大,部分产品信息可能未能及时更新,下单前请与销售人员确认好实时在库数量,谢谢合作!

CUB4CL40产品概述

Self-Contained batteries eliminate the need for external power and prevent loss of count if power fails. Also provides for remote or portable applications. Battery operation also means elimination of shock hazard and allows the use of 2-conductor bell wire for count signals and micro-power input signals. Batteries are easily replaceable (2 “N" Cells, alkaline) and average battery life is four years. Various count inputs allow use with switch contacts or high speed pulse outputs from electronic sensors and circuits. The reset function can be disabled, set up for front panel reset, remote reset, or both. The CUB's micro-circuits can accurately and silently accumulate enough counts in one hour to completely wear out an ordinary E.M. counter. More over, it can repeat this performance many times with just one set of batteries. Internal “micro-assembly" construction withstands many times the “g" force of shock and vibration compared to conventional construction. CUB counters also feature elastomeric contacts. This eliminates long term problems associated with contact corrosion. Battery operation, a high degree of input filtering, plus an inherent common mode rejection ratio of more than 120 dB @ 50/60 Hz, provides ultra-high immunity from electrical noise interference.

CUB4CL40产品信息

  Approvals  CSA 22.2 No. 213-M1987, EN 61010-1, File E184589, IEC 529, IEC 61010-1, IP65 (Face), Type 4X Indoor Enclosure (Face), UL Listed, UL50, UL1604  
  Brand Family  CUB  
  Brand/Series  CUB4CL Series  
  Connection Type  Screw-Clamp  
  Cut Out, Panel  2.68×1.3 "  
  Depth  0.157" (4mm)  
  Dimensions  2.95" L x 2.11" W x 1.54" H  
  Dimensions, Cutout, Inches  68 x 33 mm  
  Display Digit Height  15.2 mm  
  Display Range  0.5 in. (LCD), 0.4 in. (LED)  
  Display Type  LCD  
  Function  Ammeter  
  Material, Casing  Plastic  
  Measuring Range  -1999 to 1999 A dc  
  Memory Type  E²PROM  
  Mounting Type  Panel Mount  
  Number of Digits  3-1?2  
  Primary Type  Electronic  
  Range, Measurement  4 to 20/10 to 50 mA  
  Standards  UL, cUL Listed, CE Marked, NEMA Approved  
  Supply Voltage  9 to 28 VDC  
  Temperature Range  0 to +60 °C  
  Temperature, Opening, Maximum  60 °C  
  Temperature, Operating, Minimum  0 °C  
  Terminal Type  Screw-Clamp  
  Type  Electronic  
  Weight  1.5 lbs.  
关键词         

CUB4CL40客户还搜索了

  • 参考图片
  • 制造商 / 说明 / 型号 / 仓库库存编号
  • PDF
  • 操作

CUB4CL40相关搜索

Approvals CSA 22.2 No. 213-M1987, EN 61010-1, File E184589, IEC 529, IEC 61010-1, IP65 (Face), Type 4X Indoor Enclosure (Face), UL Listed, UL50, UL1604  Red Lion Controls Approvals CSA 22.2 No. 213-M1987, EN 61010-1, File E184589, IEC 529, IEC 61010-1, IP65 (Face), Type 4X Indoor Enclosure (Face), UL Listed, UL50, UL1604  Digital Process Meters Approvals CSA 22.2 No. 213-M1987, EN 61010-1, File E184589, IEC 529, IEC 61010-1, IP65 (Face), Type 4X Indoor Enclosure (Face), UL Listed, UL50, UL1604  Red Lion Controls Digital Process Meters Approvals CSA 22.2 No. 213-M1987, EN 61010-1, File E184589, IEC 529, IEC 61010-1, IP65 (Face), Type 4X Indoor Enclosure (Face), UL Listed, UL50, UL1604   Brand Family CUB  Red Lion Controls Brand Family CUB  Digital Process Meters Brand Family CUB  Red Lion Controls Digital Process Meters Brand Family CUB   Brand/Series CUB4CL Series  Red Lion Controls Brand/Series CUB4CL Series  Digital Process Meters Brand/Series CUB4CL Series  Red Lion Controls Digital Process Meters Brand/Series CUB4CL Series   Connection Type Screw-Clamp  Red Lion Controls Connection Type Screw-Clamp  Digital Process Meters Connection Type Screw-Clamp  Red Lion Controls Digital Process Meters Connection Type Screw-Clamp   Cut Out, Panel 2.68×1.3 "  Red Lion Controls Cut Out, Panel 2.68×1.3 "  Digital Process Meters Cut Out, Panel 2.68×1.3 "  Red Lion Controls Digital Process Meters Cut Out, Panel 2.68×1.3 "   Depth 0.157" (4mm)  Red Lion Controls Depth 0.157" (4mm)  Digital Process Meters Depth 0.157" (4mm)  Red Lion Controls Digital Process Meters Depth 0.157" (4mm)   Dimensions 2.95" L x 2.11" W x 1.54" H  Red Lion Controls Dimensions 2.95" L x 2.11" W x 1.54" H  Digital Process Meters Dimensions 2.95" L x 2.11" W x 1.54" H  Red Lion Controls Digital Process Meters Dimensions 2.95" L x 2.11" W x 1.54" H   Dimensions, Cutout, Inches 68 x 33 mm  Red Lion Controls Dimensions, Cutout, Inches 68 x 33 mm  Digital Process Meters Dimensions, Cutout, Inches 68 x 33 mm  Red Lion Controls Digital Process Meters Dimensions, Cutout, Inches 68 x 33 mm   Display Digit Height 15.2 mm  Red Lion Controls Display Digit Height 15.2 mm  Digital Process Meters Display Digit Height 15.2 mm  Red Lion Controls Digital Process Meters Display Digit Height 15.2 mm   Display Range 0.5 in. (LCD), 0.4 in. (LED)  Red Lion Controls Display Range 0.5 in. (LCD), 0.4 in. (LED)  Digital Process Meters Display Range 0.5 in. (LCD), 0.4 in. (LED)  Red Lion Controls Digital Process Meters Display Range 0.5 in. (LCD), 0.4 in. (LED)   Display Type LCD  Red Lion Controls Display Type LCD  Digital Process Meters Display Type LCD  Red Lion Controls Digital Process Meters Display Type LCD   Function Ammeter  Red Lion Controls Function Ammeter  Digital Process Meters Function Ammeter  Red Lion Controls Digital Process Meters Function Ammeter   Material, Casing Plastic  Red Lion Controls Material, Casing Plastic  Digital Process Meters Material, Casing Plastic  Red Lion Controls Digital Process Meters Material, Casing Plastic   Measuring Range -1999 to 1999 A dc  Red Lion Controls Measuring Range -1999 to 1999 A dc  Digital Process Meters Measuring Range -1999 to 1999 A dc  Red Lion Controls Digital Process Meters Measuring Range -1999 to 1999 A dc   Memory Type E²PROM  Red Lion Controls Memory Type E²PROM  Digital Process Meters Memory Type E²PROM  Red Lion Controls Digital Process Meters Memory Type E²PROM   Mounting Type Panel Mount  Red Lion Controls Mounting Type Panel Mount  Digital Process Meters Mounting Type Panel Mount  Red Lion Controls Digital Process Meters Mounting Type Panel Mount   Number of Digits 3-1?2  Red Lion Controls Number of Digits 3-1?2  Digital Process Meters Number of Digits 3-1?2  Red Lion Controls Digital Process Meters Number of Digits 3-1?2   Primary Type Electronic  Red Lion Controls Primary Type Electronic  Digital Process Meters Primary Type Electronic  Red Lion Controls Digital Process Meters Primary Type Electronic   Range, Measurement 4 to 20/10 to 50 mA  Red Lion Controls Range, Measurement 4 to 20/10 to 50 mA  Digital Process Meters Range, Measurement 4 to 20/10 to 50 mA  Red Lion Controls Digital Process Meters Range, Measurement 4 to 20/10 to 50 mA   Standards UL, cUL Listed, CE Marked, NEMA Approved  Red Lion Controls Standards UL, cUL Listed, CE Marked, NEMA Approved  Digital Process Meters Standards UL, cUL Listed, CE Marked, NEMA Approved  Red Lion Controls Digital Process Meters Standards UL, cUL Listed, CE Marked, NEMA Approved   Supply Voltage 9 to 28 VDC  Red Lion Controls Supply Voltage 9 to 28 VDC  Digital Process Meters Supply Voltage 9 to 28 VDC  Red Lion Controls Digital Process Meters Supply Voltage 9 to 28 VDC   Temperature Range 0 to +60 °C  Red Lion Controls Temperature Range 0 to +60 °C  Digital Process Meters Temperature Range 0 to +60 °C  Red Lion Controls Digital Process Meters Temperature Range 0 to +60 °C   Temperature, Opening, Maximum 60 °C  Red Lion Controls Temperature, Opening, Maximum 60 °C  Digital Process Meters Temperature, Opening, Maximum 60 °C  Red Lion Controls Digital Process Meters Temperature, Opening, Maximum 60 °C   Temperature, Operating, Minimum 0 °C  Red Lion Controls Temperature, Operating, Minimum 0 °C  Digital Process Meters Temperature, Operating, Minimum 0 °C  Red Lion Controls Digital Process Meters Temperature, Operating, Minimum 0 °C   Terminal Type Screw-Clamp  Red Lion Controls Terminal Type Screw-Clamp  Digital Process Meters Terminal Type Screw-Clamp  Red Lion Controls Digital Process Meters Terminal Type Screw-Clamp   Type Electronic  Red Lion Controls Type Electronic  Digital Process Meters Type Electronic  Red Lion Controls Digital Process Meters Type Electronic   Weight 1.5 lbs.  Red Lion Controls Weight 1.5 lbs.  Digital Process Meters Weight 1.5 lbs.  Red Lion Controls Digital Process Meters Weight 1.5 lbs.  
电话:400-900-3095
QQ:800152669
关于我们 | Amphenol简介 | Amphenol产品 | Amphenol产品应用 | Amphenol动态 | 按系列选型 | 按产品规格选型 | Amphenol选型手册 | 付款方式 | 联系我们
Copyright © 2017 www.amphenol-connect.com All Rights Reserved. 技术支持:电子元器件 ICP备案证书号:粤ICP备11103613号