FN9222-6-06产品概述
IEC connector filters are widely used for interference suppression purposes in computers and their VDU monitors, business equipment such as printers or copiers as well as in the medical instrumentation industry.
IEC 950-Compliant
250 VAC Maximum Operating Voltage at 50/60 Hertz
DC to 400 Hertz Operating Frequency
210 μA/Phase Maximum Leakage (2 μA/Phase Maximum for Medical Units)
Fast-On Terminals
–25°C to +85°C Temperature Range
6,383,000 Hours MTBF at 50°C, 230 V, Per Mil-HB-217F
Hole Diameter: 3.3 mm (1 to 15 A); 3.5 mm (16 to 20 A)